| General | |
|---|---|
| Product Name | SITE-LOG High Accuracy Voltage, Current and Temperature Data Logger |
| Model | LPMB-1 |
| Inputs | |
| Connection | Plugable terminal block for seven external channels, excitation controls and alarm outputs |
| Internal Channel | On-board thermistor temperature (-40°C ~ 70°C, -40°F ~ 158°F) |
| CH1 ~ CH4 (Voltage) | Programmable ranges for each channel: 0 ~ 20 VDC, -5 ~ +5 VDC |
| CH5 ~ CH7 (Current): | Programmable ranges for each channel: 4 ~ 20 mA, 0 ~ 50 mA. |
| Resolution | 0.0018% |
| Accuracy | Thermistor: ±0.2°C(0°C ~ 70°C, 32°F ~ 158°F) Voltage channel: ±0.05% @ 25°C for 20V, 10V, 5V channels ±0.1% @ 25°C for 2V channel Current channel: ±0.1% FSR @ 25°C |
| Input Impedance (voltage ch) | > 1 MOhms |
| Load Resistor (Current ch) | 12 Ohms |
| Over voltage/current Protection | up to ±40 VDC for voltage channels up to ±100mA for current channels |
| Alarms | |
| Channel Alarms | Two editable alarm thresholds per channel. |
| Alarm Output | ALARM1 & A2/E terminal strips can be configured as alarm outputs. Alarm-On: MOSFET(N-Channel) switch on Alarm-Off: MOSFET(N-Channel) switch off Max Power: 200mA @ 24VDC |
| Alarm-On Delay | Programmable 0 - 10 minutes delay with 1-minute increment. |
| Alarm Indicator | On-board LED becomes red when in alarm condition. |
| On-board Memory | |
| Size | 8 Mega bytes (4MB readings). |
| Data Retention | Over 20 years. |
| Sampling | |
| Sampling Interval | 20 milliseconds to 12 hours programmable. (external power supply required if interval less than five seconds) |
| Logging Mode | Stop recording or FIFO when memory is full. |
| Logging Activation | Programmable instant, start delay or field push button activation. |
| Communications | |
| Interface | USB (Mini-USB-B) (USB-A-mini USB-B Cable included) AUX(RJ11) for TTL level RS232 communications. |
| Baud Rate | Auto-detect baud rate from 2400 to 115200 bps on both USB and AUX. |
| Battery | |
| Power | Built-in 3.6V Lithium Battery. |
| Battery Life | 10 years based on 1 minute sampling interval. |
| Software | |
| SiteView (Sold separately) | Configuration, downloading, plotting, real-time view, custom calibration and custom equation. |
| Software Requirement | Computer with 1.0 GHz or faster processor 1 GB Memory or higher 10 GB of available hard-drive space or higher Windows XP with SP2 or later, Vista, Window 7,8,10 At least one USB port or one COM port. |
| Physical | |
| Material | Aluminum enclosure. |
| PCB Treatment | Conformal coating. |
| Dimension | 88 X 64.2 X 24 mm (3.46 X 2.53 X 0.95 inches). |
| Weight | 200g |
| Mounting | Probe/wall-mount holes for hanging/mounting. |
| Others | |
| LED Indicator | Tri-Color LED: (can be disabled for power saving) Normal Sampling: light green when sampling. Alarm: red when sampling. Low Battery: amber when sampling. |
| Excitation Control | A2/E terminal strip can be configured as excitation control output for driving the power of connected devices. Warm-up delay interval settings: 10 to 240 seconds with 10-second increment. |
| Operating Environment | -40 ~ +70 °C (-40 °F ~ 158 °F), 0 ~ 95% RH non-condensing. |
| Clock Accuracy | ±1 mintue per month. |
| Approval | CE, FCC |
| Sampling Interval | Enabled Channel | Logging Capacity |
|---|---|---|
| 1 minute | 1 | 8 years |
| 1 minute | 2 | 4 years |
| 1 minute | 8 | 1 year |
| 10 seconds | 1 | 485 days |
| 10 seconds | 2 | 242 days |
| 10 seconds | 8 | 60 days |
| 1 second | 1 | 48 days |
| 1 second | 2 | 24 days |
| 1 second | 8 | 6 days |
| 100 milliseconds | 1 | 4 days |
| 100 milliseconds | 2 | 2 days |
| 100 milliseconds | 8 | 14.4 hours |